DESCRIPTION
 
Browave's EDFA has an output power of 16dBm and the historical measurement data can be configurable by users. The monitoring alarm function was provided with real time display on the front panel and alarm signal transmitted out throung the serial communication ports (RS232 and/or RJ45)
FEATURES
  Dimension:483 x 44 x 221.5 mm
  Intelligent Module with Alarm,Auto Shutdown and RS-232 interface and RJ45 interface.
  Dual -48VDC PowerSupply for System Protection.
  ACC,ALC,AGC,and APC Operating Modes
APPLICATIONS
  Metro Networks and CATV
DWDM Networks
  Optical Add / Drop and Cross Connects
  Pre-amplification or Booster Amplification
MONITORING INFORMATION
#
Alarm Description
1
Loss of Input Power
2
Degraded Input Power
3
Loss of Output Power
4
Degraded Output Power
5
Loss of Pump Power
6
Power Supply Failure
7
Communication Port Error
8
Excessive Power Supply
9
Excessive Temperature for Laser Chip
 
Monitoring Information
1
Output Power
2
Input Power
3
Pump Current
4
Laser Chip Temperature
SPECIFICATIONS
 
Parameter
C-band
Single Channel
C-band
Gain Flattened
Wavelength Range
1530~1565 nm
1540~1565 nm
1530~1563 nm
Input Power Range
-35 ~ -18 dBm
-20 ~ +2 dBm
-24 ~ -3 dBm
Nominal Gain
N/A
N/A
20 dB
Max. Output Power
15 dBm
16 dBm
19 dBm
Max. Gain Flatness
@ All Temp.
N/A
N/A
2.0 dB
Max. Noise Figure @ Max.
Pout and Min.Pin
4.5 dB
5.5 dB
6.0 dB
Polarization-dependent Gain
0.5dB
Polarization-mode Dispersion
0.3 ps
3dB Add/Drop Gain Transient overshoot/undershoot
N/A
0.5 dB
3dB Add/Drop Gain Transient overshoot/undershoot
N/A
100 us
9dB Add/Drop Gain Transient overs hoot /undershoot
N/A
1.0 dB
9dB Add/Drop Gain Transient
Suppression Time
N/A
500 us
Power Supply Voltage
Dual -48 VDC
Mechanical Dimension
483mm(W) x 44mm(H) x 221.5mm(D)
Operating Temperature
-0 ~50